A disk won't connect

A disk that can’t connect says so in its state, with since when. Its page shows why in plain words, with the technical detail under it, and Try Again.

  • Connecting…: BeamDisk is logging in to the server. Wait a moment.
  • Retrying (amber): the server didn’t answer, or turned the login away for a reason that may pass. BeamDisk tries again by itself and says when: Trying again in 20 s.
  • Can’t connect (red): the server refused the login. Fix the cause, then click Try Again.
The disk’s page says What to do
The server can’t be reached right now. Check that the server is on, its iSCSI service is running, and the network between them works. BeamDisk keeps trying.
The server doesn’t allow this Mac to use this target. Add this Mac’s initiator name to the target’s allowed initiators on the server. The page shows the name with a Copy button. Then click Try Again.
The server refused the CHAP user name or secret. Remove the disk, then add it again with the right CHAP details.
This target needs CHAP. Remove the disk, then add it again with its CHAP user name and secret.
This target doesn’t use CHAP, but CHAP is set for it here. Remove the disk, then add it again without CHAP.
The server no longer has this target. The target was removed or renamed on the server. Remove the disk, or put the target back.
BeamDisk needs the disk’s size to be a multiple of 16 KiB. Change its size on the server to a whole number of MiB or GiB.
The CHAP secret couldn’t be read from the keychain. Remove the disk, then add it again.
Another computer is using this disk. It connects here once the other computer lets go of it. See One Mac per disk.
BeamDisk stopped twice while checking what’s on this disk (damaged data?). The disk’s contents may be damaged. Try Again checks it again.

To change a disk’s CHAP details, remove it and add it again: its data stays on the server. See Connect, eject and remove disks.

Some settings, such as CRC32C digests, apply when a disk next logs in to its server. If the server refuses the new setting, the disk keeps working with the previous one, and BeamDisk says so, with when: on the disk’s page, under New settings (The server refused them at 11:09 AM: it doesn’t support CRC32C header digests. The previous ones stay in use.), and in Settings → Connection. Choose a setting the server supports, such as When the target asks.

If every disk on one server stops connecting at once, look at the server first: its iSCSI service, its network, or a change to its allowed initiators or CHAP settings.

Still stuck? Get help.